To determine the operating status of the fully electric servo CNC coiling machine, the following aspects can be comprehensively considered:
1、 Power supply and control system inspection
1. * * Power Supply Status * *: First, check the power supply status of the servo motor to ensure that the power cord is connected properly and there is no damage or disconnection. You can use tools such as a multimeter to measure the current on the power cord and confirm if it is within the normal range.
2. * * Control System * *: Check if the control system is turned on in the correct order and if the cable connections are secure. Observe whether the indicator light of the controller lights up normally and check for any error code prompts.
2、 Motor operation status check
1. * * Current detection * *: Determine whether the servo motor is working properly by measuring its operating current. The specific operation includes turning off the servo motor, disconnecting the controller power supply, measuring the winding resistance value, and connecting the ammeter wire to measure the normal operating current of the servo motor while turning on the power supply. If the current value is within the specified range, it indicates that the motor is running normally; If the current value is too high or too low, it may be necessary to adjust the wiring or replace the motor.
2. * * Position detection * *: Manually move the servo motor to a stationary position and record the initial position value, then let the servo motor run for a fixed cycle (such as one minute), and record the final position value. Compare the changes in two position values, and if there are no abnormal changes, it indicates that the motor is working normally.
3. Oscilloscope detection: Connect the probe of the oscilloscope to the output port of the servo motor, observe the frequency, amplitude, phase and other data of the waveform to determine whether the servo motor is working properly.
3、 Numerical Control System Inspection
1. * * Programming and Parameter Setting * *: Check if the programming of the CNC system is correct and if the parameter settings meet the machining requirements.
2. * * Running stability * *: Observe the running status of the CNC system and check for any abnormal alarms or error code prompts.
4、 Other inspections
1. Encoder and Sensor: Check if the encoder and sensor are working properly, such as if the encoder is damaged and if the sensor cables are securely connected.
2. * * Mechanical part * *: Check whether the mechanical part of the servo motor rotates freely and whether there are any abnormal sounds or vibrations.
3. Lubrication and cooling system: Check whether the lubrication and cooling system is working properly, such as whether the lubricating oil and coolant are sufficient, and whether the pipelines are unobstructed.
4. * * Load Capacity Test * *: Before use, test the load capacity of the servo motor to ensure it meets the working requirements.
In summary, through the above inspections, the operating status of the fully electric servo CNC coiling machine can be comprehensively judged. During the inspection process, attention should be paid to using professional tools and instruments, and following relevant safety operating procedures. If any abnormalities or problems are found, they should be promptly addressed and repaired to ensure the normal operation and efficient processing capability of the equipment.